Power failures result in keyboard lockup, complete data loss, hardware degradation and damaged motherboards. The Back-UPS RS 1500 Extended Runtime UPS from APC® allows you to work through brief power failures or to shut down your system in the event of an extended failure. The 1500 gives you a run-time of 32 minutes with a 200 watt draw. It features three audible alarms including alarm when the battery is on, distinctive low-battery alarm and overload continuous tone alarm. Status indicator LEDs notify you of changing UPS and utility power conditions. The UPS includes additional surge-only outlets that offer protection for non-data sensitive equipment like scanners and printers without reducing the unit's available power or battery capacity. This helps to maximize battery power for equipment like a computer and monitor. Built-in fax/modem line (DSL-compatible) protection and easy-to-install safe system shutdown software all make this power protection unit something your company can't afford to live without.
Click here for RS1500 Data/User Guide.
| Output | |
| Output power capacity | 1500 VA |
| Output power capacity | 865 Watts |
| Nominal output voltage | 1500 VA |
| Max Configurable Power | 865 Watts |
| Output Connections | (6)NEMA 5-15R (2)NEMA 5-15R (Surge) |
| Input | |
| Nominal input voltage | 120 V |
| Input frequency | 47-63 Hz |
| Input connection | NEMA 5-15P with 6ft (1.8m) power cord |
| Batteries | |
| Typical Backup Time | 12.4 minutes at Half Load, 3.7 minutes at Full Load |
| Battery type | Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof |
| Typical recharge time | 8 hour(s) |
| Replacement battery cartridge | (1) RBC33 |
| Communications & Management | |
| Interface port | USB |
| Management software included | PowerChute Personal Edition |
| Control panel | LED status display with On Line : On Battery : Replace Battery and Overload indicators |
| Audible alarm | Alarm when on battery : distinctive low battery alarm |
| Surge Protection and Filtering | |
| Surge energy rating (Joules) | 420 |
| Filtering | Full time multi-pole noise filtering : 0.7% IEEE surge let-through : zero clamping response time : meets UL 1449 |
| Dataline protection | RJ-11 Modem/Fax protection (two wire single line) |
| Physical | |
| Maximum height dimensions | 14.60 inches |
| Maximum width dimensions | 3.40 inches |
| Maximum depth dimensions | 13.10 inches |
| Net weight | 25 lbs |
| Shipping weight | 26 lbs |
| Color | Biege |
| Environmental | |
| Operating Environment | 0-40 degrees C (32-104 F) : 0-95% Relative Humidity : 0-3000 meters elevation (0-10000 ft) |
| Storage conditions | -15 - 45 degrees C (5 -113 F) : 0-95% Relative Humidity : 0-15000 meters elevation (0-50000 ft) |
| Online thermal dissipation | 180 BTU/hr |
| Conformance | |
| Approvals | CCSA, FCC Part 15 Class B, FCC Part 68, UL 1449, UL 1778, UL Listed |
| Standard warranty | 2 years repair or replace |
| Equipment protection policy | $150,000 lifetime equipment protection policy |